The diesel generator set shown has a total weight of approximately 2 tons and an overall length of 3.4 meters. Structurally, the generator (power output side) is located on the left, while the diesel engine (power source) is on the right. These two parts are rigidly connected as one unit.
In this configuration, the primary vibration source is the diesel engine, and the key objective is to reduce vibration transmission between the engine, generator, and supporting structure.
Since the engine and generator are mechanically connected, isolators with excessive height or large static deflection may negatively affect alignment and normal operation.
Therefore, for separate isolation of the engine and generator, low-profile rubber isolators with small compression deflection are recommended, such as Models 33, 34, and 35. These models provide effective vibration control while maintaining structural stability.
When isolating the diesel generator set as a whole, isolators can be installed beneath the complete steel base or channel frame.
In this case, Models 17 and 19 rubber isolators are recommended to reduce vibration transmission from the entire unit to the foundation.
The selection of vibration isolators should also consider the installation environment:
Installed on ground-level foundations:
The ground itself provides good vibration absorption. In most cases, rubber isolators are sufficient.
Installed on basement floors or building slabs:
If vibration may affect nearby equipment or building structures, isolators with lower natural frequency, such as spring isolators, are recommended to achieve better low-frequency vibration isolation and prevent structural resonance.

Anlijing Vibration Reduction Technology Co., Ltd. specializes in the research, development, and manufacturing of vibration isolation products for a wide range of electromechanical equipment. The company offers five major product categories, including spring isolators, rubber isolators, air-film vibration isolators, air-cushion vibration isolators, and wire rope isolators, with thousands of models and specifications to meet diverse application requirements across the electromechanical industry.
In addition to standard products, Anlijing provides comprehensive vibration control services such as on-site vibration measurement, isolation system design, and customized product development, delivering reliable and effective vibration reduction solutions tailored to specific operating conditions.
Vibration damping case of diesel generator
2026-02-05
Pipe Support Vibration Isolation Design for MAU Systems
2026-02-05
Common Causes of Vibration in Cooling Towers
2026-02-05
Precision Instrument Vibration Control Solutions
2026-02-05
Installation method of membrane air flotation damper
2026-02-05
How to Solve Vibration and Noise Issues in Water Pumps?
2026-02-05
Transformer Vibration Isolation Solution
2026-02-05
Case Study on Vibration Remediation of Rooftop Air Conditioning Equipment
2026-02-05
What are the reasons why air dampers do not inflate?
2026-02-05
Vibration isolation characteristics of different types of pumps
2026-02-05
A case of vibration reduction of an air-cooled module unit on the roof of a large hotel
2026-02-05
Vehicle, ship, aviation equipment control system, medical equipment, mobile electronic instruments buffer energy absorption
Material:stainless steel Features: ...
查看详情
Vibration isolation and buffering of vehicle-mounted, ship-based, cabinet chassis, camera, drone and other equipment
Material: 304 stainless steel wire ...
查看详情
On-board hard disks, small on-board equipment, small shipborne equipment, fire and communication equipment
Material: 304 stainless steel plywo...
查看详情
It is used in water pumps, fans, cooling towers, diesel generators, air compressors, chillers and other equipment
Material: Nitrile rubber Character...
查看详情
Office equipment, air conditioning units, electronic equipment, small generators, and other light machinery
Material: natural rubber, 304 stain...
查看详情
I don't know how to solve the low-frequency vibration problem of the equipment?
--Please contact the vibration reduction engineer at sales@anlijing.com